(3) The following functions and two plug-in options can be used with the inverter produced in June 2010 or later.
Check the serial number printed on the rating plate or on package.
Item
Added parameter setting values
Added parameters
Changed parameter setting ranges
Mitsubishi inverter protocol
(computer link communication)
Modbus-RTU communication
Error message
(4) BACnet MS/TP protocol and the following functions can be used with the inverter produced in August 2010 or
later. Check the serial number printed on the rating plate or on package.
Item
Added parameter setting values
Added parameters
(5) The following functions can be used with the inverter produced in April 2012 or later.
Check the serial number printed on the rating plate or on package.
Item
Added parameter setting values
Added parameters
Pr. 30 Regenerative function selection setting value "100, 101, 120, 121"
Pr. 54 CA terminal function selection and 158 AM terminal function selection setting value
"70"
Pr. 128 PID action selection setting value "70 to 101"
Pr. 178 to Pr. 189 (input terminal function selection) setting value "50, 51, 77 and 78"
Pr. 190 to Pr. 196 (output terminal function selection) setting value "49 to 54, 67, 149 to 154,
167"
Pr.573 4mA input check selection setting range "2, 3, 4"
Pr. 147, Pr. 296, Pr. 297, Pr. 414, Pr. 415, Pr. 498, Pr. 502, Pr. 505 to Pr. 515 , Pr. 665, Pr. 753
to Pr. 769, Pr. 774 to Pr. 779, Pr. 826 to Pr. 865, Pr. 870, Pr. 997, Pr. 999, Pr.CH, AUTO,
Pr. 263 Subtraction starting frequency setting range "0 to 120Hz, 9999" to "0 to 400Hz,
9999"
Pr. 885 Regeneration avoidance compensation frequency limit value setting range "0 to
10Hz, 9999" to "0 to 30Hz, 9999"
⋅ Multi-command
⋅ Model information monitor
⋅ Cumulative power (32-bit) for a special monitor
⋅ Model information monitor
⋅ Cumulative power (32-bit) for a real time monitor
⋅ LOCd Password locked
⋅ E.2
Option fault
⋅ E.OP2 Communication option fault
⋅ E.PCH Pre-charge stop
⋅ E.LCI 4mA input fault
Pr. 52 DU/PU main display data selection setting value "67, 81 to 86"
Pr. 54 CA terminal function selection setting value "67, 85"
Pr. 158 AM terminal function selection setting value "67, 86"
Pr. 190 to Pr. 196 (output terminal function selection) setting value "82 and 182"
Pr. 331 RS-485 communication station number setting range "0 to 127"
Pr. 332 RS-485 communication speed setting range "768"
Pr. 549 Protocol selection setting range "2"
Pr. 774 to Pr. 776 PU/DU monitor selection 1 to 3 setting range "67, 81 to 86"
Pr. 390, Pr. 726 to Pr. 729
Pr. 52 DU/PU main display data selection setting value "64"
Pr. 128 PID action selection setting value "40", "41", "140", "141"
Pr. 753 Second PID action selection setting value "40", "41", "140", "141"
Pr. 774 PU/DU monitor selection 1 setting value "64"
Pr. 775 PU/DU monitor selection 2 setting value "64"
Pr. 776 PU/DU monitor selection 3 setting value "64"
Pr. 561 PTC thermistor protection level
Pr. 986 Terminal 10 calibration for PTC thermistor
Changed Functions
Changed Functions
Changed Functions
401