Mitsubishi FR-F720-00046-NA Instruction Manual page 155

Table of Contents

Advertisement

Types of Monitor
Increments
Cumulative power
0.01kWh/
0.1kWh
*6
Power saving
effect
Variable
according
to
Cumulative saving
parameters
power
*6
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
PTC thermistor
0.01kΩ
resistance
PID measured
0.1%
value 2
PLC function
0.1%
output
BACnet reception
1
status
BACnet token pass
1
counter
BACnet valid
1
APDU counter
BACnet
communication
1
error counter
Terminal CA output
level
Terminal AM
output level
*1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04, FR-PU07).
*2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0. When
the operation panel (FR-DU07) is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added up from 0.
*3
The actual operation time is not added up if the cumulative operation time before power supply-OFF is less than 1h.
*4
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
*5
The setting depends on capacities. (FR-F720-02330 (FR-F740-01160) or lower/FR-F720-03160 (FR-F740-01800) or higher)
*6
Since the panel display of the operation panel is 4 digits in length, the monitor value of more than "9999" is displayed as "----".
*7
When the output current is less than the specified current level (5% of the rated inverter current), the output current is monitored as 0A. Therefore,
the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor compared to the
inverter or in other instances that cause the output current to fall below the specified value.
Pr. 52 Parameter
Pr. 54 (CA)
Setting Value
Pr. 158 (AM)
Parameter
PU main
Setting
DU LED
monitor
Value
25
*4, *5
50
51
52
53
54
*1
55
*1
×
56
×
57
64
67
×
81
82
83
84
85
(Pr. 54 only)
86
(Pr. 158 only)
Monitor display and monitor output signal
Full-scale
value of the
terminal CA
and AM
Displays the cumulative power amount
according to the output power monitor
×
Use Pr. 170 to clear the value.
(Refer to page 148.)
Inverter
Displays energy saving effect monitor
50
capacity
You can change the monitor to power
saving, power saving average value,
charge display and % display using
×
parameters.
(For details, refer to page 167.)
100%/
52
C42 or C44
Displays the set point, measured value and
100%/
deviation during PID control
53
C42 or C44
(For details, refer to page 271.)
×
Displays ON/OFF status of the input
×
terminal on the PU
(Refer to page 147 for DU display)
Displays ON/OFF status of the output
×
terminal on the PU
(Refer to page 147 for DU display)
Displays ON/OFF status of the input terminal
×
of the digital input option (FR-A7AX) on the
DU (Refer to page 147 for details)
Displays ON/OFF status of the output
terminal of the digital output option (FR-
×
A7AY) and relay output option (FR-A7AR)
on the DU (Refer to page 147 for details)
Displays the PTC thermistor resistance at
terminal 2 when PTC thermistor protection
×
is active.
(0.10kΩ to 31.5kΩ) (Refer to page 107)
100%/
Displays the measured value
67
C42 or C44
(For details, refer to page 271.)
Desired values can be output from terminal
CA and AM using the PLC function.
70
100%
Refer to the FR-F700 PLC function
programming manual for details of the PLC
function.
Displays the reception status of BACnet
×
communication
(Refer to page 249 for details)
×
Displays the count of received token
×
Displays the count of valid APDU detection
×
Displays the count of communication error
Displays actual output current level of
terminal CA which is controlled by BACnet
85
20mA
communication
(Refer to page 249 for details)
Displays actual output voltage level of
terminal AM which is controlled by BACnet
86
10V
communication
(Refer to page 249 for details)
Description
145
4

Advertisement

Table of Contents
loading