Install The Glass Media; Install The Baffle; Install The Glass Door; Adjust The Air Shutter To Ensure Proper Flame Appearance - Superior Fireplaces DRL6500 Installation And Operation Instruction Manual

Table of Contents

Advertisement

Innovative Hearth Products
DRL6500 Linear Direct-Vent Gas Fireplaces
3. To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
Figure 34 - Electronic Pilot

Install the Glass Media

15.
1. See Page 58 for instructions on Installing the Glass Media.

Install the Baffle

16.
1. With the baffle oriented as shown in Figure 35, slide the rear tabs into the slots in the back panel.
Figure 35 - Baffle
2. While sliding the tabs into the slots, slide the front lip of the baffle under the clips in the firebox ceiling.

Install the Glass Door

17.
1. See Page 59 for instructions on Installing and removing the glass door.

Adjust the Air Shutter to Ensure Proper Flame Appearance

18.
• Air shutter adjustment should only be performed by a qualified professional service techni-
• Ensure glass door is in place and sealed during adjustment.
40
should engulf the flame rod (Figure 34).
Igniter
Flame
Rod
Baffle
cian.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Pilot Hood
Firebox Ceiling
Clip
Tabs
Back Panel
WARNING
Installation
900077-00, 01/2018