Optional: Install The Firebox Liners; Install The Logs, Volcanic Stone, And Glowing Embers; Install The Glass Door; Adjust The Air Shutter To Ensure Proper Flame Appearance - Superior Fireplaces DRT4240DEN-B Installation And Operation Instruction Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT4200 Series Direct-Vent Gas Fireplaces

Optional: Install the Firebox Liners

16.
1. See Page 51 for instructions: Installing the Firebox Liners.

Install the Logs, Volcanic Stone, and Glowing Embers

17.
1. See Pages 54–56 for instructions on Installing the logs, volcanic stone, and glowing embers.

Install the Glass Door

18.
1. See Pages 57–58 for instructions on Installing and removing the glass door.

Adjust the Air Shutter to Ensure Proper Flame Appearance

19.
• Air shutter adjustment should only be performed by a qualified professional service technician.
• Ensure glass door is in place and sealed during adjustment.
• Soot will be produced if the air shutter is closed too much. Any damage due to sooting,
resulting from improperly setting the air shutter, is not covered under the warranty.
• The air shutter rod and nearby appliance surfaces are hot. Exercise caution to avoid injury
while adjusting flame appearance.
Flame Appearance and Sooting
The flame should be blue at the base, and yellow-orange in the body of the flame.
When the fireplace is first lit, the entire flame may be blue and will gradually turn yellow-orange during the first 15
minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air
shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the
tips of very long orange flames. Sooting results in black deposits forming on the logs, fireplace inside surfaces, and
on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter
opening. To achieve a warm yellow-orange flame with an orange body that does not soot, the shutter opening must
be adjusted between these two extremes.
Air Shutter Adjustment Guidelines
If smoke or soot is present, first check the log set positioning to ensure that the flames are not impinging on any
of the logs. If the log set is properly positioned and a sooting condition persists, then the air shutter should be
opened more.
The more offsets in the vent system, the wider the air shutter will need to be opened.
An fireplace operated with the air shutter opened too far may have flames that appear blue and transparent.
These weak, blue, and transparent flames are termed anemic.
Propane models may exhibit flames that candle or appear stringy. If this condition is present and persists, adjust
the air shutter to a more closed position, then operate the fireplace for a few more minutes to ensure that the
flame normalizes and the flames do not appear sooty. The following chart is provided to help achieve the correct
air shutter adjustment for your installation.
Table 28 - Air Shutter Adjustment Guidelines
Amount of Primary
If air shutter is
closed too far
If air shutter is
open too far
Flame Color
Air
Flame will
Air shutter gap should be increased
be orange
Flame will
Air shutter gap should be decreased
be blue
WARNING
CAUTION
Air Shutter Adjustment
Installation
900636-01, 01/2017
43

Advertisement

Table of Contents
loading