Install the Glass Media

13.
1. See Page 57 for instructions on Installing the Glass Media.

Install the Baffle

14.
NOTE: The baffle is factory-installed. Remove to install the vent restrictor (Page 20).
1. With the baffle oriented as shown in Figure 33, slide the rear tabs into the slots in the back panel.
Figure 33 - Baffle
2. While sliding the tabs into the slots, slide the front lip of the baffle under the clips in the firebox ceiling.

Install the Glass Door

15.
1. See Page 58 for instructions on Installing and removing the glass door.

Adjust the Air Shutter to Ensure Proper Flame Appearance

16.
• Air shutter adjustment should only be performed by a qualified professional service technician.
• Ensure glass door is in place and sealed during adjustment.
• Soot will be produced if the air shutter is closed too much. Any damage due to sooting,
resulting from improperly setting the air shutter, is not covered under the warranty.
• The air shutter door and nearby appliance surfaces are hot. Exercise caution to avoid
injury while adjusting flame appearance.
Flame Appearance and Sooting
The flame should be blue at the base, and yellow-orange in the body of the flame.
When the fireplace is first lit, the entire flame may be blue and will gradually turn yellow-orange during the first 30
minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air
shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at
the tips of very long orange flames. Sooting results in black deposits forming on the fireplace inside surfaces and on
exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter
opening. To achieve a warm yellow-orange flame with an orange body that does not soot, the shutter opening must
be adjusted between these two extremes.