Internal Reference Operation; External Reference Operation - Texas Instruments DAC5687 EVM User Manual

Table of Contents

Advertisement

www.ti.com
4.5

Internal Reference Operation

The full-scale output current is set by applying an external resistor (R1) between the BIASJ pin of the
DAC5687 device and ground. The full-scale output current can be adjusted from 20 mA down to 2 mA by
varying R1 or changing the externally applied reference voltage. The full-scale output current, IOUTFS, is
defined as follows:
IOUT
+ 16
FS
where VEXTIO is the voltage at pin EXTIO. This voltage is 1.2 V typical when using the internally provided
bandgap reference voltage source.
4.6

External Reference Operation

The internal reference can be disabled and overridden by an external reference by connecting a voltage
source to EXTI/O and connecting EXTLO to +3.3VA (jumper W1 installed between pins 1 and 2). The
specified range for external reference voltages must be observed (see the DAC5687 data sheet
(SLWS164) for details).
SLWU017B – APRIL 2005 – Revised March 2007
Submit Documentation Feedback
V
EXTIO
R1
Circuit Description