Fan and fan blank

Fan population guidelines

Configuration
One processor,
non-redundant
One processor,
redundant
Two processors,
non-redundant
Two processors,
redundant
In the redundant fan mode:
If one fan rotor fails, the system continues to operate without redundancy. This condition is indicated
o
by a flashing amber Health LED.
If two fan rotors fail, the system shuts down.
o
The minimum fan requirement to make this server bootable is three fans for a single processor and
o
four fans for a dual processor configuration.

Fan blank

WARNING:
internal system components to cool before touching them.
To remove the component:
Power down the server (on page 26).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6
Fan
Fan
Blank
Fan
Fan
Fan
Fan
Fan
Blank
Fan
Fan
Fan
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Fan
Blank
Blank
Fan
Fan
Blank
Fan
Blank
Fan
Fan
Fan
Fan