REMOVAL OF GAS COMBO VALVE
1. Shut off all gas and electrical power to the unit.
2. Open fryer door and locate valve. (Fig. 36)
3. Follow steps 1-8 under the Removal of Burners and disassemble any burner obstructing your working area
for the combo valve.
4. Note and remove all combination valve wiring.
5. With a 7/16" wrench loosen the pilot tube compression nut. (Fig. 37)
Fig. 36
Fig. 37