4. Refer to steps 1-8 under removal of burner and remove burners as required to access the
thermopile bracket and its hardware.
5. Slide the control housing heat shield down. (Fig. 29)
6. With a 1/2" wrench remove the pilot tubing from the pilot assembly. (Fig. 30)
Fig. 29
Fig. 30