Inspection and maintenance
9.8.2

Cleaning the siphon

Cleaning the condensate trap
WARNING
Danger to life due to poisoning!
If the condensate trap is not filled, poisonous flue gas can escape.
▶ Only turn off the trap filling program during maintenance, and turn it
back on at the end of maintenance.
▶ Make sure that the condensate drains off properly.
Damage resulting from an insufficiently cleaned siphon are excluded
from the warranty.
▶ Clean the siphon regularly.
1. Remove the hose on the left of the condensate trap.
2. Actuate the locking lever at the bottom to release the siphon.
3. Pull the condensate trap down to remove it and drain it.
1.
2.
3.
Fig. 81 Removing the condensate trap
64
1. Unscrew the cleaning cap.
2. Check the gasket for cracks, deformation or breakage and replace if
3. Clean the condensate trap, and check that the aperture towards the
4. Insert a new gasket if required.
5. Tighten the cleaning cap up to the locking position.
2.
3.
Fig. 82 Cleaning the condensate trap
▶ Remove and check the gasket for cracks, deformation or breakage
0010021752-001
Fig. 83 Removing the gasket on the top of the condensate trap
required.
heat exchanger is clear.
1.
3.
2.
and replace if required.
Greenstar 2000 – 6 721 820 552 (2021/02)
5.
4.
0010017273 -001
0010017274-001