Fault finding and diagnosis
Description
247
System fault boiler electronics / basic
controller
249 V
Internal software error
250 V
Default software error
251 V
Flash test error
252 V
Stack overflow
253 V
RAM test error
254 V
Eeprom test error
256 V
System fault boiler electronics / basic
controller
257
System fault boiler electronics / basic
controller
258 V
Internal watchdog error
259 V
AD reference error
262 V
Internal OS error
76
Remedy
▶ Reset burner control - factory reset.
▶ Check electrical connections of burner control.
▶ Replace burner control.
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Reset control unit / burner control unit - factory reset.
▶ Reconnect electrical connections at control unit correctly.
▶ Replace the control unit/burner control unit.
▶ Reset burner control - factory reset.
▶ Check electrical connections of burner control.
▶ Replace burner control.
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on the board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
▶ Restart the appliance to see if the problem re-occurs.
▶ Check the electrical connections on board (check for loose wires etc.).
▶ Check the code plug, if present, is not damaged.
▶ Replace the code plug, if present and required.
▶ Replace the control unit (PCB).
Greenstar 2000 – 6 721 820 552 (2021/02)