Waste pipe connection
 Figure 32
Alternatively if the first option is not possible an internal kitchen,
bathroom or washing machine waste pipe etc. can be used.
Ensure that the condensate drain pipe is connected "down stream" of
the waste trap and that the condensate drain enters into the top of the
pipe using a swept tee.
1
1
Fig. 32 Waste pipe disposal
[1]
Condensate discharge from appliance
[6]
75mm sink waste trap
Condensate pump
 Figure 33
Where direct connection to "gravity discharge" pipework is not
physically possible, or where very long internal runs would be required to
reach a suitable discharge point, condensate should be removed using a
proprietary condensate pump, of a specification recommended by the
condensate pump manufacturer.
• The pump outlet should discharge to a suitable "gravity discharge"
outlet.
– The condensate then flows, by gravity, through the 22mm plastic
pipe to the condensate discharge point.
8
1
7
Fig. 33 Condensate pump example
[1]
Condensate discharge from appliance
[7]
Condensate pump
[8]
Pipework transition
[C]
Gravity discharge pipework
Proprietary condensate pump
▶ Ensure minimum and maximum pump lifting heights are followed as
per condensate pump manufacturers instructions.
Greenstar 2000 – 6 721 820 552 (2021/02)
75mm
6
min.
75mm
6
min.
Max.
C
Min.
Pre-Installation
29