The following steps are provided to assist with the installation of the VPM5580TC module. If you are
unfamiliar with the VPM5580TC module it is suggested you follow these steps in order to help prevent
problems and reduce the overall installation time.

2.1 Installation Steps

Step 1: Mount the VPM5580TC
To connect the VPM5580TC to the main CPU
board, perform the following steps:
1. Remove the nuts from the two threaded studs
at the bottom corners of the VPM5580TC section
of the control unit.
2. Fasten the two standoffs provided with the interface
card to the threaded studs, as shown below.
3. Line up the female connector on the interface
card with the male connector labelled VPM on
the control unit and firmly press into place.
4. Fasten the two screws provided with the
interface card to the standoffs to secure the
card in place.
Note: The main control panel should remain
powered down until the Communiqué is powered
up and all stations have been initialized.

Getting Started

S
E
C
T
5
firealarmresources.com
I
O
N
2
Note: Permanent damage could result to the
VPM5580TC or the control panel if the connections
are offset. You must ensure that proper connections
are made before applying power to the control unit.
Step 2:Connect the Keybus (Section 2.2)
Connect the 4 wire Keybus in accordance to the
diagram in Section 2.2 "Keybus Wiring".
Step 3:Enroll the VPM5580TC Module (Section 2.3)
Enroll the VPM5580TC module in accordance to the
guideline provided in Section 2.3 "Enrolling the
VPM5580TC module" .
Step 4:Connect the PL-513 or PSC04 Controller
(Section 2.4)
If the installation also includes Automation items
connect the PL-513 or PSC04 Controller in accordance
to the diagram provided in Section 2.4 "Connecting
the PL-513 or PSC04 Controller".
Step 5:Connect the EMS-100 Thermostat and
Temperature Sensors (Section 2.5)
If you will be adding temperature control to the system,
connect one or more EMS thermostats to the
VPM
5580
TC
according to F
you will be connecting additional sensors.
Step 6:Program the VPM5580TC
All parameters of the VPM5580TC can be programmed
via any local touch tone telephone. Follow the guideline
provided in Section 4 "How to Program" .
Step 7:Test the System
Test the VPM5580TC using both local and remote
telephones to ensure both operate properly. Check
all programmed labels and the operation of all
functions including Automation items and thermostats,
if connected.
Temperature control will work only on
control panels that support Escort
5580 models and software version of
2.X or higher. Does not support heat
pump applications.