Programming Temperature Control Operation; Selecting An Address For A Thermostat; Programming How Occupancy Settings Are Turned On - DSC Communique VPM5580TC Installation Manual

Hide thumbs Also See for Communique VPM5580TC:
Table of Contents

Advertisement

T
E
M
P
Occupancy settings do not need to be turned off.
A thermostat will follow the occupancy setting it is
in until switched to another one.
9.2 Programming Temperature
Control Operation
To tell the VPM5580TC how temperature control
should work, program the operation of each
thermostat and each Occupancy setting in
programming sections [800] through [882]. For
each thermostat, you need to:
Select an address (see section 9.3)
Enroll the thermostat and program various
operating options (see section 9.5)
For each Occupancy setting used on each
thermostat you need to:
Select how the Occupancy setting will follow
schedules
and/or
programming an output condition for the
Automation item (see section 9.4)
Select which schedules (if any) the Occupancy
setting will follow (see section 9.6)
Select which modes (if any) the Occupancy
setting will follow (see section 9.7)
Select which PGM output (if any) the
Occupancy setting will follow (see section 9.8)
Programming sections for thermostat 01 ([800]
through [819]) are described in detail in sections
9.3 to 9.7. If additional thermostats are connected,
program them in the same manner.
In addition, you may need to program one or more
of the following:
The On Time, Off Time and Days of the Week of
each schedule to be used (see section 7).
Thermostat Labels, to program what the
VPM5580TC will say when referring to a thermostat
item (see section 3.4).
Mode Labels, to program what the VPM5580TC
will say when referring to a mode (see section 3.4).
E
R
A
T
U
PGM
outputs
by
firealarmresources.com
R
E
C
O
9.3 Selecting an Address for a
Thermostat
Each EMS thermostat connected in the system
must be given an address (01-04). Do the following
at each thermostat on the system:
1. On the EMS thermostat, press and hold the
Mode key and the Fan key together for 10
seconds. The display on the EMS thermostat
will show a 2-digit number from 01-99. This
number is the current address of the thermostat.
2. Use the arrow keys on the EMS thermostat to
scroll through the numbers until the desired
number is displayed (01-04). The VPM5580TC
only supports thermostat addresses 01-04.
3. To save the thermostat address and exit, press
either the Mode key or the Fan key on the EMS
thermostat.
Thermostats must be assigned in
sequence. If you remove a thermostat
for any reason, you must reassign
address numbers 01, 02 and 03 to the
remaining thermostats.
9.4 Programming How Occupancy
Settings Are Turned On
You can program occupancy settings to follow
pre-set schedules, and/or the state of PGM outputs.
PGM outputs can be programmed to activate when
events occur (e.g. system arming). See your
system's Installation Manual for more information
on PGM outputs.
Enter a 2-digit number in sections [803]-[881] to
determine how each occupancy setting for each
thermostat will operate.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Occupancy Setting Schedule/
Output Condition ............. sections [803] - [881]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
(00) Does not follow schedules or PGM outputs
Occupancy settings can always be switched
manually through the VPM5580TC. If only manual
control is desired (no automatic control), then
program the Occupancy Mode Schedule /Output
Condition as [00] (No Schedule or Output Control).
23
N
T
R
O
L

Advertisement

Table of Contents
loading

Table of Contents