Thermostat Control Programming - DSC Communique VPM5580TC Installation Manual

Hide thumbs Also See for Communique VPM5580TC:
Table of Contents

Advertisement

P
R
O
G
R

Thermostat Control Programming

Sections 'e.g. [800]' to 'e.g. [804]' show the programming to be completed for each thermostat, using thermostat
1, Day occupancy setting as an example. Complete the programming for additional occupancy settings and
thermostats in a similar manner. Record your programming in the sections that follow the example.
e.g. [800]
Thermostat 1 Options
Default Option ON
OFF
01
Thermostat 1 enrolled
OFF
02
Thermostat 1 EMS-OTS sensor connected
ON
03
Thermostat 1 Heat enabled
ON
04
Thermostat 1 Cool enabled
OFF
05
Day Setting follows Sched./Output always
OFF
06
Night Setting follows Sched./Output always
OFF
07
Aux. Setting follows Sched./Output always
OFF
08
Away Setting follows Sched./Output always
e.g. [801]
Thermostat 1 Day Occupancy Setting: Schedule Assignment
Default
Option
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
e.g. [802]
Thermostat 1 Day Occupancy Setting: Mode Assignment
Default
Option
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
OFF
l _ _______ l
e.g. [803] Thermostat 1 Day Occupancy Setting: Schedule/PGM Output Condition
Default: 00
l_____l_____l
[00] No Schedule or PGM Output control
[01] PGM Output control only
[02] Schedule control only
e.g. [804] Thermostat 1 Day Occupancy Setting: PGM Output Follower
Default: 00
l_____l_____l
A
M
M
I
N
ON
01
Follows Schedule 1
02
Follows Schedule 2
03
Follows Schedule 3
04
Follows Schedule 4
05
Follows Schedule 5
06
Follows Schedule 6
07
Follows Schedule 7
08
Follows Schedule 8
09
Follows Schedule 9
10
Follows Schedule 10
11
Follows Schedule 11
12
Follows Schedule 12
13
Follows Schedule 13
14
Follows Schedule 14
15
Follows Schedule 15
16
Follows Schedule 16
ON
01
Assigned to Mode 1
02
Assigned to Mode 2
03
Assigned to Mode 3
04
Assigned to Mode 4
05
Assigned to Mode 5
06
Assigned to Mode 6
07
Assigned to Mode 7
08
Assigned to Mode 8
(Valid Entries are 00-04)
(Valid entries are PGM Outputs 01-14; 00= not used)
firealarmresources.com
G
W
O
R
K
OFF
Thermostat 1 not enrolled
Thermostat 1 EMS-OTS not connected
Thermostat 1 Heat disabled
Thermostat 1 Cool disabled
Day Set. follows Sched./Output only if mode ON
Night Set. follows Sched./Output only if mode ON
Aux. Set. follows Sched./Output only if mode ON
Away Set. follows Sched./Output only if mode ON
OFF
Does not follow Schedule 1
Does not follow Schedule 2
Does not follow Schedule 3
Does not follow Schedule 4
Does not follow Schedule 5
Does not follow Schedule 6
Does not follow Schedule 7
Does not follow Schedule 8
Does not follow Schedule 9
Does not follow Schedule 10
Does not follow Schedule 11
Does not follow Schedule 12
Does not follow Schedule 13
Does not follow Schedule 14
Does not follow Schedule 15
Does not follow Schedule 16
OFF
Not assigned to Mode 1
Not assigned to Mode 2
Not assigned to Mode 3
Not assigned to Mode 4
Not assigned to Mode 5
Not assigned to Mode 6
Not assigned to Mode 7
Not assigned to Mode 8
[03] Schedule OR
[04] Schedule AND PGM Output
46
S
H
E
E
PGM Output
T
S