TRAINING MANUAL
WM3001H*A
When the Turbo Steam Generator is
installed in the washer, the hoses to the
dispenser should fit into the tubing
guides.
Be particularly careful when removing and
replacing the water input hose to the
steam generator. There is a check valve
that fits into the input port. The valve
sometimes comes off and is stuck in the
hose. This could cause the water not to
flow, which would cause the steam
generator to malfunction.
Pull the check valve out of the hose gently
and replace it into the water input port.
Then slide the hose onto the port and
install the clamp.
Newer models have a retainer built into
the check valve to eliminate this issue.