Inlet Valve Assembly - LG WM3001HRA Training Manual

Hide thumbs Also See for WM3001HRA:
Table of Contents

Advertisement

TRAINING MANUAL
The valve assemblies introduce water to the tub and cause dispensing of the various
laundry products. Hot water enters only through the main wash compartment. Cold
water is directed by the four solenoids to the various laundry products.
(See the dispenser section on pages 34 ~ 35.)
The solenoids can be checked in TEST MODE. (See page 52.) Use a multimeter to verify
that each solenoid is receiving 120 V
proper valve is dispensing water to the appropriate dispenser compartment. This
procedure can also be used to determine that the valves are connected correctly and the
hoses are routed to the appropriate compartments after a repair.
WM3001H*A

INLET VALVE ASSEMBLY

during the TEST MODE. Also verify that the
AC
For all solenoids:
With the solenoid connected and
energized, the voltage should be 120 V
With the connector removed from the
solenoid, the resistance should be
1.0 Ω ± 20%.
Page 87
WM3001H*A
.
AC
Washer

Hide quick links: