5. Adjusting the Position of the Load Detecting Switch
If you have replaced or reassembled the lead cam (rear), you must adjust the position of the
load detecting switch, as the load detecting switch is likely to have been displaced away from he
load lever.
1) Making Adjustments
Check to find out if the load detecting switch [1] is pushed by the load lever [2]. Otherwise,
loosen the screw [4] of the load detecting switch plate [3] to make adjustments.
COPYRIGHT © 1998 CANON INC. CANON STAPLER SOTRER-L1 MS-C1 REV.0 NOV. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
[2]
[1]
[3]
[4]
Figure 5-114