10.16 Setting the boiler flue sweep
function
With the boiler set in flue sweep mode, it is
possible to exclude some boiler automatic
functions making check and control opera-
tions easier.
• Enter "programming mode" by pressing
the 13 and 15 keys simultaneously for 5
seconds (Fig. 10.21) until HiS (Boiler His-
tory) appears on the LCD display (Fig.
10.22).
12
13
Fig. 10.21
Fig. 10.22
• Scroll through the various menus by
pressing the keys 13 (back) or 15 (for-
ward), until ChS (Chimney sweep) ap-
pears on the LCD display (Fig. 10.23).
• Press the 14 key for 1 second to enter the
selected menu.
Fig. 10.23
MAINTENANCE
17
16
15
14
Flue sweep function at minimum output
in domestic hot water mode
• Press keys 13 and 15 (Fig. 10.21) at the
same time until the LCD display displays
the letters LP that alternate with the heat-
ing water temperature value (e.g.45), in-
dicating the activation of the "flue sweep
function" at minimum output (Fig. 10.24).
Fig. 10.24
Flue sweep function at minimum output
in heating mode
• By pressing 15 (Fig. 10.21) it is possible
to change power in flue sweep mode: with
the letters hP on the LCD display which
alternate between the heated water tem-
perature (i.e.32), we are in the "flue sweep
function" at the minimum power during
heating (Fig. 10.25).
Fig. 10.25
- 83 -