Technical Data M300V.3035 Sm - Biasi M300V.2025 SM User Manual And Installation Instructions

Combi
Table of Contents

Advertisement

4.7

Technical data M300V.3035 SM

Heat input
Nominal net
central heating
(A)
Nominal net
domestic hot water
(A)
Nominal gross
central heating
(B)
Nominal gross
domestic hot water
(B)
Minimum net
C.H. - D.H.W.
(A)
Minimum gross
C.H. - D.H.W.
(B)
Useful output
Maximum (central heating)
Maximum (domestic hot water)
Minimum (C.H. - D.H.W.)
Maximum condensing (central heating)
Maximum condensing (domestic hot
water)
Minimum condensing (C.H. - D.H.W.)
- 36 -
TECHNICAL INFORMATION
kW
31,0
BTU/h 105776
kW
34,7
BTU/h 118401
kW
34,4
BTU/h 117412
kW
38,5
BTU/h 131425
kW
3,8
BTU/h 12966
kW
4,2
BTU/h 14392
kW
30,6
BTU/h 104411
kW
34,1
BTU/h 116354
kW
3,6
BTU/h 12284
kW
33,6
BTU/h 114648
kW
37,7
BTU/h 128638
kW
4,0
BTU/h 13649
Central heating
Min/Max flow temperature settings*
Maximum pressure
Minimum pressure
Available head (in 1000 l/h)
Seasonal efficiency G20
(c)
Seasonal efficiency G31
(c)
* to the minimum useful output
referred to the net calorific value at 15 °C and
(A)
1013,25 mbar: G20 = 34,02 MJ/m
kg
referred to the gross calorific value at 15 °C and
(B)
1013,25 mbar: G20 = 37,78 MJ/m
kg
The value is used in the UK Government's Standard
(C)
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been calcu-
lated have been certified by a notified body.
Values subject to tolerance
(D)
Domestic hot water
Min/Max temperature settings
Maximum pressure
Minimum pressure
Flow rate minimun
Flow rate 30° rise
(D)
Flow rate 35° rise
(D)
Flow rate 40° rise
(D)
°C
25 - 80
kPa
300
bar
3,0
kPa
30
bar
0,3
kPa
32,0
bar
0,32
%
n.a.
%
n.a.
- G31 = 46,34 MJ/
3
- G31 = 50,37 MJ/
3
°C
35 - 55
kPa
1000
bar
10
kPa
30
bar
0,3
l/min
2,5
l/min
16,9
l/min
14,3
l/min
12,4

Hide quick links: