Gas supply pressures
Gas
Nom
Natural G20
Min
Max
Nom
Propane G31
Min
Max
Gas rate maximum - central heating
Natural G20
Propane G31
Gas rate maximum - domestic hot water
Natural G20
Propane G31
Gas rate minimum – C.H. - D.H.W.
Natural G20
Propane G31
Electrical data
Voltage
Frequency
Nominal Power consumption
Minimum Power consumption
Stand-by Power consumption
Protection degree
External fuse rating
Internal fuse rating
TECHNICAL INFORMATION
Pa
mbar
2000
20
1700
17
2500
25
3700
37
2500
25
4500
45
m
/h
3,28
3
kg/h
2,41
m
/h
3,67
3
kg/h
2,70
m
/h
0,40
3
kg/h
0,30
V~
230
Hz
50
W
116
W
11
W
3
IPX5D
A
3
N° 2 - 2
A
AF
Flue design
Boiler type
B23P C13 C33 C43 C53 C63 C83 C93
Ø Coaxial
Ø Twin split pipes
Ø Roof
Ø Roof
Nominal heat flow rate
(A) (E)
Exhaust temperature
(E)
Mass flow rate
(E)
Flue gas figures
Nominal heat input
(A) (E)
CO
content with gas G20
2
O
content with gas G20
2
CO content with gas G20
Exhaust temperature
(E)
NOx class
Weighted NOx
Values refer tests with a 1 m flue working at the
(E)
nominal heat input
CO
contents - central heating
2
Nominal heat input
(A) (E)
CO
content with gas G20 (range
2
min - max)
CO
content with gas G31 (range
2
min - max)
Minimum heat input
(A) (E)
CO
content with gas G20 (range
2
min - max)
CO
content with gas G31 (range
2
min - max)
mm
60/100
mm
80/80
mm
60/100
mm
80/125
kW
34,7
°C
78,0
kg/s
0,02
kW
34,7
%
8,5 - 9,5
%
4,8
ppm
200,0
°C
78,0
6
ppm
16
kW
31,0
%
8,5 - 9,5
9,6 -
%
10,6
kW
3,8
%
8,5 - 9,5
9,5 -
%
10,5
- 37 -