4.2.26 Operation mode selection (Pr. 79)

Pr. 79 "operation mode selection"
Used to select the operation mode of the inverter.
The inverter can be run from the parameter unit (PU operation) or by operation via
CC-Link (CC-Link operation).
At power-on (factory setting), the CC-Link operation mode is selected.
Parameter
Number
79
<Setting>
In the following table, operation from the parameter unit is abbreviated to PU operation.
Pr. 79
Setting
At power-on, the CC-Link operation mode is selected. Pressing the
on the parameter unit switches between the PU operation mode (PU) and CC-Link
0
operation mode (NET).
For these modes, refer to the settings 1 and 2.
Operation mode
1
PU operation
mode (PU)
CC-Link operation
2
mode (NET)
Factory
Setting
Setting
Range
2
0 to 2
Running frequency
Digital setting by key operation
of parameter unit
CC-Link master unit
Related parameters
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239 (multi-speed
operation)
Pr. 180 to Pr. 183 (input terminal
(remote output) function
selection)
Function
unit
106