Para-
Func-
meter
tion
Number
PU main display data
52
selection
57
Restart coasting time
58
Restart cushion time
Shortest acceleration/
60
deceleration mode
Reference I for
61
intelligent mode
Reference I for
62
intelligent mode
acceleration
Reference I for
63
intelligent mode
deceleration
65
Retry selection
Stall prevention
operation level
66
reduction starting
frequency (Note 4)
Number of retries at
67
alarm occurrence
68
Retry waiting time
Retry count display
69
erasure
Special regenerative
70
brake duty
71
Applied motor (Note 4)
PWM frequency
72
selection
Reset selection/
disconnected PU
75
detection/PU stop
selection
Parameter write
77
disable selection
Reverse rotation
78
prevention selection
Operation mode
79
selection (Note 4)
Setting
Name
Range
0, 23, 100
0 to 5 s,
9999
0 to 60 s
0, 1, 2,
11, 12
0 to 500A,
9999
0 to 200%,
9999
0 to 200%,
9999
0, 1, 2, 3
0 to 400Hz
0 to 10,
101 to 110
0.1 to 360 s
0
0 to 30%
0, 1, 3, 5, 6,
13, 15, 16,
23, 100,
101, 103,
105, 106,
113, 115,
116, 123
0 to 15
0 to 3,
14 to 17
0,2
0,1,2
0 to 2
70
PARAMETERS
Minimum
Factory
Setting
Setting
Increments
1
0
0.1 s
9999
0.1 s
1.0 s
1
0
0.01A
9999
1%
9999
1%
9999
1
0
0.01Hz
60Hz
1
0
0.1 s
1 s
1
0
0.1%
0%
1
0
1
1
1
14
1
0
1
0
1
2
Custo-
Refer
mer
To:
setting
93
95
95
96
96
96
96
98
86
98
98
98
89
100
101
102
104
105
106