Maintenance (Replacement And Repair); Routine Maintenance Visits; First Line Maintenance; Standard Interface Card Replacement (667/1/47221/100) - Siemens 667/HB/47200/000 Manual

Wimag vehicle detection system general handbook
Table of Contents

Advertisement

17 Maintenance (Replacement and Repair)

Before starting any maintenance work, read the Safety Warning on page 2 of this
Handbook.

17.1 Routine Maintenance Visits

The interval between visits depends on local conditions but typically would be every six
months. Routine maintenance consists of the following:
1. Confirm that the battery levels for each detector is within expected/required levels
2. Confirm battery level for the repeater is within expected / required levels.
Battery level information is found by using the Traffic Dot application software ( reference
section 1.2).

17.2 First Line Maintenance

17.2.1 Standard Interface Card Replacement (667/1/47221/100)

Full details of the 'interface card' GUI can be found in the following document;
Part Number
667/HB/47200/100
Table 16 : Interface Card Configuration and User Guide
If the interface card requires replacing the following actions should be followed;
1. Ensure the 'configuration sheet' is available for reference.
2. Important: Disconnect the Ethernet connection from the front of the interface card.
3. Pull the interface card from the WiMag communications rack.
4. Prior to fitting the replacement interface card; ensure the 'configuration link' has
been removed. This will ensure the interface card is in 'factory default mode'.
5. Fit the standard interface card and connect the Ethernet connection back onto the
front of the card.
6. Connect to the interface card using the IP address 10.10.10.10
7. Set the interface card as per the configuration sheet. Any deviations from the
interface card should be recorded on said sheet.
8. On completion of the settings – click on the 'Apply Settings' and allow the unit to
reboot.
Version
11
Last Editor
Jeerh, Manpreet
Document
WIMAG GENERAL HANDBOOK
Name
Copyright © Siemens Mobility Limited 2012. All Rights Reserved.
Document Description
BVD Interface User Manual
Page 92 of 117
Siemens Mobility Limited
Sopers Lane, Poole, Dorset
Status
Issued
Date
March 2020
Doc. No.
667/HB/47200/000
BH17 7ER

Advertisement