Verify Enb Operational Status; Figure 3-20: Reboot - Baicells Neutrino430 Installation Manual

Indoor 4x250mw two-carrier tdd enodeb
Hide thumbs Also See for Neutrino430:
Table of Contents

Advertisement

Figure 3-20: Reboot

3.5.9 Verify eNB Operational Status

When the eNB is finished rebooting, check the eNB status using the eNB GUI and the OMC:
NOTE: Once the eNB is mounted at its intended destination and powered on, recheck the
status settings.
eNB GUI: Go to Basic Setting > Basic Info and check the Cell Status field (Figure 3-21). It
should show Active. Also, check that GPS Sync is reported as Synchronized.
OMC: Go to eNB > Monitor to see if the Cell Status shows Active and the Sync Status shows
GPS Synchronized (Figure 3-22).
NOTE: Ensure you have selected ALL in the display settings window in the OMC > eNB > Monitor
page to view Cell Status and Sync Status as shown in Figure 3-23.