3.3 Connect Cables

WARNING:
Ensure the antenna is connected before powering up the eNB. The wireless
signal transmission power can cause bodily injury and damage to the eNB and RF power
amplifier devices.
The power and interface cables for the Neutrino430 can be connected in three different
configurations depending on your specific site requirements or setup:
PWR power supply, OPT backhaul,
PWR power supply, WAN/PoE+ backhaul,
WAN/PoE+ power supply and backhaul,

3.3.1 PWR Power Supply, OPT Backhaul Configuration:

Connect the cables for the PWR power supply, OPT backhaul configuration, as shown in the
following steps. Refer to Figure 3-6.
1. Connect the AC power supply to the power (PWR) interface on the eNB and the other end
to a power outlet
2. Connect the optical fiber cable to the optical (OPT) interface on the eNB.
3. Connect the other end of the optical fiber cable to the Ethernet port on the Ethernet switch.

Figure 3-6: PWR Power Supply, OPT Backhaul Configuration

section 3.3.1
section 3.3.3
.