3.2 Install eNB on Ceiling or Wall
The eNB unit bracket is assembled in manufacturing before packing. The only action required by
the installer is to attach the assembly to the ceiling or wall.
Follow the steps below to install the Neutrino430 eNB on the ceiling or wall.
Caution:
•
Ceiling thickness must be at least 0.71 in (18 mm) and must bear a weight of at least
11.02 lb (5 kg).
•
If the ceiling is made of drywall or gypsum, it must be reinforced before installation
to ensure the eNB is secure.
1. Fit the wall bracket on the ceiling or wall, as shown in Figure 3-2. Mark the drilling locations
using a pencil or marker.
2. Drill four holes in the wall to match the size of the bracket holes.
Figure 3-2: Mark and Drill the Holes
3. Install the drywall anchors and the screws, as shown in Figure 3-3.
Figure 3-3: Install Drywall Anchors and Screws
14