GEM 1441 cPos-X Operating Instructions Manual page 25

Intelligent electro-pneumatic positioner
Hide thumbs Also See for 1441 cPos-X:
Table of Contents

Advertisement

Number
Parameter Description
S01
Switching
Number of
cycle
switching
counter
cycles can
be reset by
the cus-
tomer
S02
Warning
Warning
threshold
threshold
switching
switching
cycles
cycles of
the pilot
valves
-
Switching
Indicator
cycles
for valve
warning ra-
wear on
tio
the pilot
valve mod-
ule
P26
Initializa-
Quantity of
tion quant-
calibration
ity of calib-
points
ration
when ini-
points
tializing
S09
Operating
Operating
time OPEN
time of the
valve in
open direc-
tion
S10
Operating
Operating
time
time of the
CLOSED
valve in
closed dir-
ection
P21
Decay time
Decay time
D-compon-
of the D-
ent
component
P22
Differential
Amplifying
component
the D-com-
ponent
P23
Propor-
P-amplific-
tional amp-
ation of the
lification
positioner
P20
Dead zone Setting the
manual
dead zone
P44
Dead zone
Dead zone
value auto
value auto
P24
Dead
Automatic
zones func-
dead zone
tion
adjustment
www.gemu-group.com
Settings
Initial set-
ting
0 to
0 (is adjus-
214748360
ted auto-
0
matically)
0 to
50,000,000
2,147,483,6
00
0.0 to
0.0% (is ad-
100.0%
justed
automatic-
ally)
1 to 19
9
0.0 to 99.9
0.0 s (is ad-
s
justed
automatic-
ally)
0.0 to 99.9
0.0 s (is ad-
s
justed
automatic-
ally)
1 to 5000
100 ms
ms
0.0 to
0.0
100.0
0.1 to
1.0 (is ad-
100.0
justed
automatic-
ally)
0.1 to
1.0%
25.0%
0.1 to 25% 1% (is ad-
justed
automatic-
ally)
manual,
manual
auto
25 / 33
Number
Parameter Description
Set value,
Current set
manual
value for
manual op-
eration
S06(.1)
Set value
Compar-
ison of set
value and
valve posi-
tion
S06(.2)
Valve posi-
Compar-
tion
ison of ac-
tual value
and valve
position
-
I set value
Current tar-
input
get value
signal
-
I actual
Signal ana-
value out-
logue out-
put
put
-
Position
Control de-
control de-
viation for
viation
positioner
S05(.1)
Absolute
Valve abso-
position
lute posi-
init.
tion end
(CLOSED)
positions
S05(.2)
Absolute
Valve abso-
position
lute posi-
init. (open)
tion end
positions
-
Current ab-
Current ab-
solute posi-
solute posi-
tion
tion of the
travel
sensor
P43
Travel
Direction of
sensor dir-
action of
ection of
the travel
action
sensor
P33
Analogue
Valve posi-
output min
tion at out-
put signal
of 4 mA
P34
Analogue
Valve posi-
output max
tion at out-
put signal
of 20 mA
P16
Set value
Lower
limit
range of
CLOSED
the set
value limit
14 Parameter list
Settings
Initial set-
ting
0.0 to
-
100.0%
0.0 to
-
100.0%
0.0 to
-
100.0%
0.0 to 22.0
-
mA
0.0 to 22.0
-
mA
-100.0 to
-
100.0%
0.0 to
- (is adjus-
100.0%
ted auto-
matically)
0.0 to
- (is adjus-
100.0%
ted auto-
matically)
0.0 to
-
100.0%
rise, fall
rise
0 to 100%
0%
0 to 100%
100%
0 to 100%
0%
GEMÜ 1441 cPos-X