Upon installation, the ice hopper must be sanitized before the unit is started. For ice
hopper sanitizing, perform the procedure in Table 3. After initial installation, the sani-
tizing procedure is run through the user interface Reference page number, etc.
Step
1
Disconnect power cord from the unit, if connected.
2
Remove the cover from the top of the unit.
3
Unplug the quick disconnect attached to the hopper lid. photo
Use a 1/4" nut driver to loosen hopper lid bracket. Slide the bracket off of the
4
hopper lid to gain access to the hopper. photo
Spray the inside of the hopper, agitator and the agitator lid with cleaning
5
solution and wipe them dry with a clean cloth.
Spray the inside of the hopper, agitator and the agitator lid with sanitiz-
6
ing solution and allow the pieces to air dry.
Remove the clear front from the ice chute by lifting it straight up, as
7
shown in Figure 3.
Spray the lid and clear ice chute with cleaning solution and wipe them
8
dry with a clean cloth.
9
Spray the lid and clear ice chute with sanitizing solution and let air dry.
10
Reassemble the lid and clear ice chute.
11
Tighten the lid bracket and reattach the quick disconnect.