General Vent Maintenance; Log Replacement; Glass Replacement; Removing Valve - HAMPTON BAY H35U-NG Owners & Installation Manual

Table of Contents

Advertisement

maintenance

General Vent Maintenance

Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1) Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2) Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
3) Check for evidences of excessive condensa-
tion, such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused by
having excessive lateral runs, too many elbows,
and exterior portions of the system being ex-
posed to cold weather.
4) Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.

Log Replacement

The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door to carefully remove the logs. The pilot
light generates enough heat to burn someone. If for
any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagram
under Log Installation.
Note: Improper positioning of logs may create
carbon build-up and will alter the unit's
performance which is not covered under
warranty.

Glass Replacement

Your stove is supplied with high temperature, 5
mm Neoceram ceramic glass that will withstand
the highest heat that your unit will produce. In the
event that you break your glass by impact, purchase
your replacement door from an authorized Hampton
dealer only, and follow our step-by-step instructions
for replacement.
1) Lift off the Cast Top.
44
2) Open the 2 latches of the Glass Front.
3) Lift the Glass Front Assembly up.
4) Remove the glass and replace with the new
glass.
5) Replace the door and Cast Top.
®
Replacement Part # 940-324 Glass
WARNING: Do not operate appliance
with glass panel removed, cracked
or broken. Replacement of the glass
should be done by a licensed or quali-
fied service person.
Note: Wearing gloves will protect your hands
while handling glass.

Removing Valve

If your valve requires maintenance or replacement,
use the following instructions:
Note: Always close off the gas supply before
1) If optional fan is installed, disconnect power
source to stove.
2) Remove access panel.
3) Disconnect gas line to stove.
4) Disconnect 3/8" NPT pipe from 90
valve.
5) Disconnect the two (2) switch wires from valve.
6) Disconnect piezo wire.
7) Lift off the Cast Top and lift out the front door.
Latches
8) Carefully remove the logs, embers and rock-
wool.
9) Remove burner (see diagram below).
Note: Use a mag-
netic screwdriver
if possible.
Hampton® H35U Direct Vent Freestanding Gas Stove
removing the valve.
elbow on
o

Advertisement

Table of Contents
loading

This manual is also suitable for:

H35u-lp

Table of Contents