Horizontal Venting With Two 90; Elbows; Horizontal Venting With Two 90 Elbows - HAMPTON BAY H35U-NG Owners & Installation Manual

Table of Contents

Advertisement

installation

Horizontal Venting with Two 90

One 90
elbow = Two 45
o
Option
V
A)
3' (914 mm) min.
B)
4' (1.2 m) min.
C)
5' (1.5 m) min.
D)
6' (1.8 m) min.
E)
7' (2.1 m) min.
F)
8' (2.4 m) min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open). Refer to the "Vent Restrictor
Position" section.
Horizontal Venting with Two 90
Option
H
A)
1' (305 mm) max.
B)
2' (610 mm) max.
C)
3' (914 mm) max.
D)
4' (1.2 m) max.
E)
5' (1.5 m) max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open) Refer to the "Vent Restrictor Position" section.
22

Elbows

o
elbows.
o
H + H1
With these options, maxi-
mum total pipe length is 30
2' (610 mm) max.
feet with minimum of 8 feet
total vertical and maximum
3' (914 mm) max.
8 feet total horizontal.
4' (1.2 m) max.
Please note minimum 1
5' (1.5 m) max.
foot between 90
is required.
6' (1.8 m) max.
8' (2.4 m) max.
Elbows
o
One 90
Elbow = Two 45
Elbows
o
o
V
H + H1
2' (610 mm) min.
3' (914 mm) max.
3' (914 mm) min.
5' (1.5 m) max.
5' (1.5 m) min.
6' (1.8 m) max.
7' (2.1 m) min.
7' (2.1 m) max.
9' (2.7 m) min.
6' (1.8 m) max.
V
elbows
o
With these options, max.
total pipe length is 30 feet
with min. of 9 feet total ver-
tical and max. 8 feet total
horizontal.
Please note minimum 1
foot between 90
elbows
o
is required.
Hampton® H35U Direct Vent Freestanding Gas Stove

Advertisement

Table of Contents
loading

This manual is also suitable for:

H35u-lp

Table of Contents