H35 Direct Vent Gas Fireplace
H35 Direct Vent Gas Fireplace
WARNING:
If the information in these instructions are not followed ex-
actly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-838
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
MODELS:
H35-NG2 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.hampton-fi re.com
H35-LP2 Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
11/09/09

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY H35-NG2

  • Page 1 H35 Direct Vent Gas Fireplace H35 Direct Vent Gas Fireplace Installation Manual www.hampton-fi re.com MODELS: H35-NG2 Natural Gas H35-LP2 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed ex- What to do if you smell gas: Do not try to light any appliance actly, a fi...
  • Page 2 WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.
  • Page 3: Unit Dimensions

    Congratulations! ® You are the owner of a state-of-the-art Hampton Gas Stove by REGENCY FIREPLACE PRODUCTS . The H35-2 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi...
  • Page 4: Table Of Contents

    Gas Pipe Pressure Testing ..........27 Conversion from NG to LP ..........28 Conversion to Lower BTU Rating ........32 Optional Brick Panel ............33 Log Set Installation ............33 Double Door Removal ..........34 Optional Side Shelves Installation .......35 ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 5: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies NOTE: Hampton ® units are constantly being each Direct Vent Freestanding Gas Stove. improved. Check the label on the unit and if We have printed a copy of the contents here there is a difference, the label on the unit is for your review.
  • Page 6 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 7: Installation

    This may be the fl oor, or it can be an 18 gauge copper wire from the steel raised up on a platform to enhance its visual Fuels: H35-NG2 is approved for use with chassis ground must be attached. impact. The appliance may be installed on natural gas.
  • Page 8: General Safety Information

    Propane" section. through a living area, where children may H35-NG2 & H35-LP2 Clearances come in contact with it. 6) Test Gas Pressure. Refer to the "Gas Pipe A Side Wall to Unit 6-1/2"...
  • Page 9: Locating Your Gas Stove

    14" - 16" and tie a loose knot in the or remove the grounding prong cord on the inside to prevent the power cord from this plug. from being pulled out. Diagram 2. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 10: Venting Introduction

    "Venting pipe venting systems, in combination with the with the H35-NG2, and H35-LP2. The warranty Arrangement" section to determine if they are Direct Vent Freestanding Gas Stoves, H35-NG2 will be voided and serious fi...
  • Page 11: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 12: 4" X 6-5/8" Rigid Pipe

    46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 13 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 14: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent Pro are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 15: Rotating 45 O Elbow For Horizontal Terminations

    85%) May be installed in Manufactured (Mobile) Homes after fi rst sale. NOTE: See "Vent Restrictor Position" section for installation instructions for the Vent Restrictor Position. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 16: Venting Arrangements

    *If this is an outside corner, the minimum dis- tance between the vent and the outside corner is 6” (15cm). See “F” on the diagram in the "Exterior Vent Terminal Locations" section. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 17 7' Max. between 90 elbows is 5' Max. 9' Min. 8' Max. required. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrictor Position" section. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 18 5' Max. 5' Min. between 90 elbows is 6' Max. 6' Min. required. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrictor Position" section. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 19: Vertical Termination With Co-Linear Flex System

    Note: Must remove 4 screws from stove collar and rotate 180 to have collar facing straight back. Secure into place with 4 screws. Straight Vertical Terminations Vent Restrictor set at 1-3/4" open (fully open), Position "A" ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 20: Dv Stove Horizontal Vent Kit

    Cut a 9-1/2" x 9-1/2" (241mm x 241 using snow blowers, make sure terminal. mm) square hole on both the interior snow is not directed towards vent and exterior wall. termination area. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 21 Stove Paint. framing out a square that the cap can be mounted on. Hint: leave an extra 12" to 16" of length, this will make the fi nal assembly easier to work with. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 22: Dura-Vent Termination Kit

    Wall Thimble Alternate Pipe Length *Adj.Pipe Length Horizontal Termination Caps *90 Elbow *24" Pipe Length Dura-Vent Basic Horizontal Kit # 46DVA-KHB 1 90 Elbow 1 Wall Thimble Cover 1 Horiz. Sq. Term. Cap ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 23: Dura-Vent Horizontal Installations

    The female locking lugs will not be visible from the outside on the Black Pipe or fi ttings. They may be located by examining the inside of the female ends. Diagram 2a ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 24: Dura-Vent Vertical Termination

    You may Diagram 4 wish to relocate the appliance or to offset, as shown in Diagram 8 to avoid cutting load bearing members. Diagram 6 ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 25 1-1/4". Slip the fl ashing over 16/12 to 18/12 2.13 under the shingles (shingles should overlap half the fl ashing) as per Diagram 10. over 18/12 to 20/12 2.29 over 20/12 to 21/12 2.44 ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 26: Converting

    Retro Connector may be completed with chimney condition exists. Do not operate the sections of black direct vent pipe, together appliance until the problem is corrected. Diagram 2 with an adjustable length. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 27: Cathedral Ceilings

    DETECTOR. DO NOT USE OPEN fl ashing under the upper shingles and on top FLAME FOR LEAK TESTING. of the lower shingles approximately half of the fl ashing should be under the shingles. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 28: Aeration Adjustment

    The aeration adjustment gears are located on Valve Description the right side of the burner box. Remove the The manifold pressure is controlled by a regulator Hampton ® Logo plate on the right side of the built into the gas control, and should be checked 1) Gas on/off knob unit to access the adjustment gears.
  • Page 29: Conversion From Ng To Lp

    Remove the glass door (refer to Reinstall new burner orifi ce LP stamped the glass door section in the manual). #51 and tighten. Fig.3 Remove the logs, embers, and brick panels (if used). ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 30: Installation Of The Dc Sparker

    ) Reassemble the black protection cap (Fig. 6). Plug up the Piezo hole with the plastic bushing. Before Fig. 6 WARNING! Also check that the pilot and main burner injectors are appropriate for the gas type. After ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 31 10) Attach the ground wire to the DC spark Connect the DC spark generator wires mounting bracket. to the SIT Valve with the screw, which is provided in the kit. 14) Tie up the loose wire with the wire clip. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 32 These instructions must Battery be left with the appliance. Compartment Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield. Heat Shield ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 33: Conversion To Lower Btu Rating

    8) Reinstall new burner orifi ce (NG stamped #37 or LP stamped #52) and tighten. 9) Reverse steps 3) and 2). 10) Set aeration setting. See settings under aeration adjustment in this manual. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 34: Optional Brick Panel

    2) Remove the log set if installed. 3) Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket. Diagram 2 Back Panel Embers Embers ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 35: Double Door Removal

    Log E)02-45 and across the cutout on Log REMOVAL A)02-43. 1) Remove the right door by unfastening the 2 right hinges (2 screws per hinge). Repeat for the left door. A)02-43 C)02-44 E)02-45 Notch Cutout ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 36: Optional Side Shelves Installation

    - tighten 2 screws (shown in step 2b) as shown below. 8) Repeat on other side. c) Install 2 screws partially onto bracket in locations shown below - in preparation for installation. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 37: Wiring Diagrams

    120V A.C. power supply is needed for the fan/ receptacle. Do not cut or remove the cause improper and dangerous blower operation. grounding prong from this plug. operation. NATURAL GAS Units and Units Equipped with DC Spark Boxes ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 38: Wall Thermostat

    Use table below to determine Thermostat Wire Table REMOTE CONTROL the maximum wire length: Recommended Maximum Lead Length Use the Hampton ® Remote Control Kit approved Note: Preferable if the thermostat is installed (Two-Wire) When Using Wall for this unit.
  • Page 39: Final Check

    5) Verify that the venting and cap are unob- period before releasing gas control knob. structed. 6) Verify log placement. If the pilot cannot be ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 40: Copy Of The Lighting Plate Instructions

    Turn clockwise to adjust the fl ame higher, coun- been turned off and the unit cooled to below a terclockwise for a lower fl ame. useful heat output range the fan will shut off automatically. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 41: Maintenance

    Again, this is normal Note: If you have an incorrect fl ame pat- not block the pilot. for steel fi reboxes. tern, contact your Hampton ® dealer for further instructions. 7) Keep the area near the appliance clear and...
  • Page 42: General Vent

    Replacement purchase your replacement door from an au- of the glass should be done by a thorized Hampton ® dealer only, and follow our 4) Lift fan off of the 2 pins, tip back and pull step-by-step instructions for replacement.
  • Page 43: Removing Valve

    See as- sembly steps 1-12. 2) Check for leaks and manifold pressure. See Gas Pressure Test instructions. 3) To reinstall valve, reverse instructions for removing valve assembly, steps 13-19. ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 44: Parts List

    1=Charcoal Grey, 5=Majolica Brown, 942-371** Casting - Bottom Skirt 118) 910-897 High Temperature Wire 7=Seaside Sand 942-867** Casting - Leg Harness - Fan End 948-219 Hampton ® Logo Plate 119) * Grommet for Power Cord 904-209 Concealed Hinge 134) 740-049 Rear Panel 740-069...
  • Page 45: Burner & Log Assembly

    630-008 Burner Tray Firebox Gasket 260-560 Air Shutter Gear Assembly - Male Burner Box 791-969 Conversion Kit from Natural Gas to Propane *Note: Not available as a replacement part. BRICK PANEL SET ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 46 NOTES ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 47 NOTES ® Hampton H35-2 Direct Vent Freestanding Gas Stove...
  • Page 48: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Hampton product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 49 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...