14
PROFLAME II REMOTE CONTROL OPERATING INSTRUCTIONS

PROFLAME I REMOTE CONTROL OPERATING INSTRUCTIONS

IMPORTANT:The Proflame Transmitter 2 is an integrated part of the
Proflame 2 System, which consists of these elements:
Proflame 2 Transmitter, to be used in conjunction with:
Integrated Fireplaces Control (Proflame 2 IFC)
The Proflame 2 Transmitter provides for controlling the following hearth
appliance functions:
1.
Main Burner On/Off
2.
Main Burner flame modulation (6 levels)
3.
Choice of standing or intermittent pilot (CPI/IPI)
4.
Thermostat and Smart thermostat functions
5.
Accent light modulation (6 levels)**
6.
Split flow valve**
7.
Comfort Fan speed modulation (6 levels)**
** This feature is not available on all models.
The Proflame Transmitter uses a streamline design with a simple button
layout and informative LCD display (Fig. 1). A Mode Key is provided to
index between the features and a Thermostat Key is used to turn on/off
or index through Thermostat functions (Fig. 1 & 2). Additionally, a Key
Lock feature is provided (Fig. 22).
Figure 1: Proflame Transmitter
Figure 2: Transmitter LCD Display
Note: May not be exactly as
shown as hand-held may be
silver or black.
14 |
Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove
919-829
TECHNICAL DATA
REMOTE CONTROL
Supply Voltage
Ambient temperature
ratings
Radio Frequency
WARNING: THE TRANSMITTER AND RECEIVER ARE RADIO
FREQUENCY DEVICES. PLACING THE RECEIVER IN OR
NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE.
ATTENTION!
- Turn "OFF" the main gas supply of the appliance during installation or
maintenance of the Receiver device.
- Turn "OFF" main gas supply to the appliance prior to removing or rein-
serting the batteries.
- In case of remote control malfunction, turn off the IFC device using the
"ON/OFF" main switch.
- For installation / maintenance, switch off the IFC device removing main
power supply plug.
OPERATING PROCEDURE
Pairing the remote control to remote receiver/battery
holder (if required)
Power the receiver. Press the "PRG" button located on the top right hand
side of receiver, see the receiver instruction (*). The Receiver will "beep"
three (3) times to indicate that it is ready to synchronize with a Transmitter.
Install the 3 AAA type batteries in the Transmitter battery bay, located on
the base of the Transmitter. (fig. 3) With the batteries already installed in
the Transmitter, push the On button. The Receiver will "beep" four times to
indicate the Transmitter's command is accepted and sets to the particular
code of that Transmitter. The system is now initialized.
(*) The receiver may be independent or integral to the IFC hearth ap-
pliance control module. The receiver instruction may not be indepen-
dent when part of the IFC.
Figure 3: Battery Compartment
1
4.5V (three 1.5V AAA batteries)
0 - 50
C (32 - 122
F)
o
o
315 MHZ
06.10.20