GAS MAINTENANCE - RECOMMENDED ANNUAL ROUTINE
Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts
In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is
operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check.
Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for
can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox,
increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your
local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually.
Clean
Glass
Interior bricks / panels
Burner ports & burner air shutter
Fan blades
Log set
Pilot orifices
Pilot hood (change as needed)
Flame sensor (electronic ignition models)
Flame electrode
Burner orifice
Thermocouple (millivolt models)
Thermopile (millivolt models)
Gas Leak Tests
Check main gas line connection to valve
Check shut off valve connections
Check connection at gas valve outlet
Check connection at main burner orifice
Check pilot fuel line at valve and at pilot
assembly
920-324
Inspect
Pilot assembly
Burner
Pressure relief gaskets/doors
Flue connector gasket if present
Door seal
Firebox
Venting
Batteries (remote handheld, remote receiver,
DC sparker, change as needed)
Burner media (change as needed)
Air shutter setting
Wiring
1
Regency
maintenance

Gas Maintenance

Check
Voltage on thermocouple/thermopile (mil-
livolt models)
Ohms reading on flame sense (electronic
ignition models)
Inlet/outlet fuel pressures as per rating plate
Voltage/ohms readings on gas valve
Ohms reading to on/off switch circuit (Mili-
volt models)