Specific Data - Io-Link; Process Data; Parameter Overview - GEM 1242 Operating Instructions Manual

Electrical position indicator
Hide thumbs Also See for 1242:
Table of Contents

Advertisement

13 Specific data – IO-Link
13 Specific data – IO-Link
Physics:
Port configuration:
Transmission rate:
Frame type in Operate:
Min. cycle time:
Vendor-ID:
Device-ID:
Product-ID:
ISDU support:
SIO operation:
IO-Link specification:

13.1 Process data

Device → Master
Name
Valve position Open
Valve position Closed
Programming mode
Master → Device
Name
Programming mode
Locate

13.2 Parameter overview

▶ All IO-Link parameters that contain sub-indexes can also be addressed in bundles via sub-index 0.
Index
Su-
Access
[Hex]
bindex
rights
0x10
0
ro
0x12
0
ro
0x13
0
ro
0x15
0
ro
GEMÜ 1242
Physics 2 (3-wire design)
Port type A
38400 baud
2.5
2.3 ms
401
124201
1242 IO-LINK
yes
yes
V1.1
Note for IO-Link: IODD files can be downloaded via the hyperlinks https://ioddfinder.io-link.com/
%20oder%20www.gemu-group.com, https://ioddfinder.io-link.com or www.gemu-group.com.
Bit
0
0 → Process valve not in Open position
1 → Process valve in Open position
1
0 → Process valve not in Closed position
1 → Process valve in Closed position
2
0 → Normal operation
1 → Programming mode
Bit
1
0 → Normal operation
1 → Programming mode
2
0 → Off
1 → On
Parameters
Vendor Name
Product Name
Product ID
Serial number
Values
Values
NOTICE
Length Data type
Default settings
6 bytes StringT
GEMUE
13
StringT
4242 IO-Link
bytes
8 bytes StringT
4242 IO-LINK
9 bytes StringT
0 – 4294967296
24 / 41
Setting options
-
-
-
-
www.gemu-group.com

Advertisement

Table of Contents
loading

Table of Contents