Maintenance and Troubleshooting

Device Status Messages

5-12
These messages appear in the messages area at the bottom of the screens.
Message
What It Indicates
Already Active
Test selected is already
running.
Backup Active
Backup has been
established and data is
flowing over the alternate
DLCI.
Blank Entries
New had been selected
Removed
from the Administer Logins
screen, no entry was made,
then Save was selected.
Command Complete
Configuration has been
saved or all tests have
been aborted.
Please Wait
Command takes longer
than 5 seconds.
Resetting Device,
Yes (or y) was entered in
Please Wait ...
the Reset COM Port usage
field of the System Paused
menu.
Test Active
No higher priority health
and status messages exist,
and a test is running.
May 1998
What To Do
Allow test to continue.
Select another test.
Stop the test.
No action needed.
No action needed.
Reenter the Login ID,
Password, and Access Level.
No action needed.
Wait until message clears.
No action needed.
Contact service provider if test
initiated by the network.
Wait until the other test ends
and message clears.
Cancel all tests from the Test
screen ( Path: main/test ).
Stop the test from the same
screen the test was started
from.