HORIZONTAL TERMINATIONS
RIGID PIPE 102MM X 175MM
The minimum components required for a basic horizontal
termination are:
1
Horizontal Termination Cap
1
90
o
Elbow
1
Rigid Pipe Adaptor (510-994)
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs to the
inside mounting surface of termination cap. For siding other
than vinyl furring strips may be used, instead of the vinyl siding
standoff, to create a level surface to mount the vent terminal.
The Terminal must not be recessed into siding. Measure the
wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl
siding), measure to outside surface of wall without siding and
add 51mm.
Flat Wall Installation
Wall Thickness
(mm)
102mm-140mm
178mm-216mm
254mm-292mm
229mm-368mm
381mm-597mm
WARNING:
Do not combine flueing components from
different flueing systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent.
When using Rigid Flue other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCap
and Regency vertical cowls are certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
AstroCap
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trade-
TM
marks of Simpson Dura-Vent Co. Inc.
Regency GF900C-2 Gas Fireplace
Vent Length Required
(mm)
152mm
229mm
305mm
279mm-371mm Adj. Pipe
432mm-610mm Adj. Pipe
and FPI
TM
Adj.Pipe Length
90
Elbow
o
Rigid PipeAdapter
(DURA VENT ONLY)
installation
Horizontal
Termination Cap
WallThimble
Direct Vent.
®