Conversion From Ng To Propane/Ulpg - Regency Greenfire GF900C Owners & Installation Manual

Hide thumbs Also See for Greenfire GF900C:
Table of Contents

Advertisement

CONVERSION KIT #468-967 FROM NG TO PROPANE/ULPG
FOR GF900 USING SIT 845 NOVA GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Each Kit contains one Propane / ULPG
Conversion Kit
GF900C Kit# 468-967
Qty.
Part #
Description
1
904-345
Burner Orifice #53
1
918-590
Decal "Converted to LP"
1
919-728
Orange Propane Label
1
918-272
Conversion to ULPG decal
1
904-529
5/32" Allen Key
1
910-037
Propane Injector
1
911-137
Pilot hood holding clip
1
919-727
Red ULPG label
1
920-039
Instruction Sheet
IT WOULD BE BENEFICIAL TO CONVERT THE APPLIANCE PRIOR TO
THE UNIT BEING INSTALLED OR WALL FACING MATERIAL FITTED
WHICH ALLOWS ACCESS TO THE BOTTOM PANEL.
PRIOR TO CONVERSION, ENSURE UNIT HAS COOLED TO ROOM
TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY
IS TURNED OFF.
1. Remove faceplate, inner frame, glass door, front trim piece and inner
panels- see instructions in this manual.
2. Remove glass crystals and stones, if installed.
3. Remove 3 screws in locations shown below to remove burner tray.
Diagram 1 - Burner Tray Screw Locations
Regency GF900C-2 Gas Fireplace
920-039
CONVERSION KIT #468-967 FROM NG TO PROPANE/ULPG
FOR GF900 USING SIT 845 NOVA GAS VALVE
IF IN DOUBT DO NOT DO THIS CONVERSION !!
4. Remove burner by removing 2 screws at the back of the burner in
locations shown below.
Diagram 2 - Burner Screw Locations
5.
Pull off the pilot cap to expose the pilot
orifice (see right).
.
6
Unscrew the pilot orifice with the Allen key and replace
with the propane pilot orifice in the kit and replace pilot
cap (see right).
7.
Remove burner orifice with a 12mm spanner and discard. Use
another spanner to hold on to the elbow below the orifice.
1
installation
GF900C-2
Pilot Cap
Pilot Orifice
Diagram 3 - Remove Pilot Cap
03/04/19
37

Advertisement