MAINTENANCE INSTRUCTIONS

1. Clean appliance and door with a damp
cloth (never when unit is hot). Never use
an abrasive cleaner. The glass should be
cleaned with a gas fireplace glass cleaner.
The glass should be cleaned when it starts
looking cloudy.
2. The faceplate is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency
uses StoveBright
®
Paint - Metallic Black #6309.
Note: Faceplates and inner panels made
from stainless steel will naturally
change color over time.
3. Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call a qualified service
person.
4. The appliance and flueing system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and flueilation
air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
5. Do not use this appliance if any part has been
under water. Immediately call a qualified
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
water.
6. In the eflue this appliance has been
serviced check that the flue-air system
has been properly resealed & reinstalled
in accordance with the manufacturer's
instructions.
7. Verify operation after servicing.
Regency GF900C-2 Gas Fireplace
GENERAL FLUE
MAINTENANCE
Conduct an inspection of the flueing system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Flueing System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
immediately.
2) Remove the Cap, and shine a flashlight
down the Flue. Remove any bird nests, or
other foreign material.
3) Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fittings. It
may be caused by having excessive lateral
runs, too many elbows, and exterior portions
of the system being exposed to cold weather.
4) Inspect joints, to verify that no pipe
sections or fittings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
maintenance

GLASS GASKET

If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-157).

GLASS DOOR

Your Regency
fireplace is supplied with high
®
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the glass
front or with a cracked or broken glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panel(s) should be
done by a licensed or qualified service per
son.

GLASS REPLACEMENT

In the eflue that you break your glass by impact,
purchase your replacement from an authorized
Regency
dealer only.
®
Replacement glass is shipped already installed
into the door frame.
CAUTION: Wear gloves when
removing damaged or broken glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualified service person.