1-8
R
I
1-8
efRigeRation
NSTALLATION
6. Push the bottom portion of the short top
rail section down over the color panel. It
helps if you lift the top with your other
hand as shown. You will hear and feel the
trim "snap" into place.
NOTE: The trim
must "snap" to be
properly positioned.
7. Use one hand to push the top rail toward
the rear of the case while using the other
hand to "snap" the top section down over
the edge of the light channel as shown.
Again, be sure it
"snaps" into place.
8. Install full length top rails using the same
procedures. Continue installing the top rails
the length of the line up. Do NOT install
last section at this time.
9. Once all except the last sections of upper
bumper and top rail have been installed
refrigerate the case line up for at least six
(6) hours. The last sections of upper bumper
and top rail should be kept inside a refrigerated
case or cooler during this time. This will
allow the bumpers and top rails to
contract.
10. Go to the right end of the line up and tap
the top rail and bumpers to close any gaps.
P/N 0518258_C
P/N 0518258_D
/ e
lectRical
Push
Lift
"Snap"
Push
"Snap"
Push
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
11. Measure and cut
last sections of top
rail and bumpers.
Use a miter box
and fine-tooth saw
to cut last bumpers
and top rail to
length. Install the
last sections.
Note: If part of plastic top rail pops loose,
remove that section of top rail and re-install
according to Steps 6 and 7 above. Trying to
reinstall only the popped part may not secure
the top rail, and may damage the top rail,
color panel and light channel.
12. Remove protective film from bumper and
top rail once installation is complete.
G
F
C
LASS
RONT
ASE
supplied silicone sealant to underside of end
trim and press firmly in place.

INSTALLING PARTITIONS

To join same temperature fixtures on different
defrost cycles, an acrylic partition kit is
required.
To join unlike fixtures, or like fixtures operat-
ing at different temperatures, a 1
(38 mm) partition kit is required.
Instructions for installing these partitions are
included with the kits.
Bumper
Miter Box
O
:
Apply field-
NLY
/
in.
1
2

Advertisement