Electrical
Merchandiser Electrical Data
Technical data sheets are shipped with this manual. The
data sheets provide merchandiser electrical data. Refer to
the technical data sheets and merchandiser serial plate for
electrical information.
Electrical Connections
All wiring must be in compliance with NEC and local
codes. All electrical connections including both supply
circuits are to be made in the electrical J-Box.
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES
Field Wiring
Field wiring must be sized for component amperes
stamped on the serial plate (refer to pg 18 for location).
Actual ampere draw may be less than specified.
Identification of Wiring
Leads for all electrical circuits are identified by colored
plastic bands. These bands correspond to the color code
sticker (shown below) located inside the merchandiser's
wireway cover.
WARNING
--LOCK OUT/ TAG OUT--
To avoid serious injury or death from electrical
shock, always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.
24