Wiring Color Code
CASE MUST BE GROUNDED
NOTE:
Refer to label affixed to case to determine the actual
configuration as checked in the "TYPE INSTALLED"
boxes.
Electrical Circuit Identification
Standard lighting for all models will be full length fluorescent
lamps located within the case at the top. The switch
controlling the lights, the plug provided for digital scale, and
the thermometer are located at the rear of the case mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.

Electrical

Electrical Service Receptacles (When Applicable)

The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heater

Field Wiring and Serial Plate Amperage

Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.

LED Driver Location

Drivers are located within the access panel that runs the
length of the rear of the case. Refer to diagram on page 4.