Refrigeration Spec Sheets - Hussmann VR3-M/F-EP Installation & Operation Manual

Table of Contents

Advertisement

Refrigeration Spec Sheets

REFRIGERATION DATA:
CASE LENGTHS
CASE USAGE
4',6',8',10',12'
MEAT/FISH
REAR STORAGE
MEAT/FISH
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) BTU'S DO NOT INCLUDE LIGHTS
2) ADD 10 BTU'S PER FOOT/PER SHELF FOR OPTIONAL LED SHELF LIGHTS
3) 2H OPTION; ADD 45 BTU/HR/FT FOR THE FRONT, ADD 5 BTU/HR/FT FOR THE REAR STORAGE.
4) 4H OPTION; ADD 80 BTU/HR/FT FOR THE FRONT, ADD 10 BTU/HR/FT FOR THE REAR STORAGE.
6) AHRI 1200 RATING POINT FOR ENERGY CONSUMPTION COMPARISON ONLY
7) USE DEW POINT FOR HIGH GLIDE REFRIGERANTS. CARE SHOULD BE TAKEN TO USE THE DEW POINT IN P/T TABLES
FOR MEASURING AND ADJUSTING SUPERHEAT. ADJUST EVAPORATOR PRESSURE AS NEEDED TO MAINTAIN THE
DISCHARGE AIR TEMPERATURE SHOWN.
8) RATING CONDITION IS NSF TYPE I, 75°F/55% RH
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
CUT
CUT IN
USAGE
OUT
(ºF)
(ºF)
TOP GRAVITY
34
33
TOP DECK
29
28
FRONT
28
26
REAR STORAGE
37
36
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
TOTAL EVAPORATOR FANS
CASE LENGTH
# OF
BLADE
EVAP
DIA.
FANS
(IN.)
4'
2
6.7
6'
6.7
4
8'
6.7
4
10'
6.7
4
12'
6
6.7
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CANOPY
LIGHTS
CASE LENGTH
H.O. LED
AMPS WATTS
43
4'
0.4
54
6'
0.5
87
8'
0.8
10'
N/A
N/A
130
12'
1.1
VERTICAL MEAT SERVICE - SELF SERVICE
HUSSMANN - VR3M/F-EP SH, +2H, & +4H OPTIONS (CHINO)
CAPACITY TOP/FRONT
TEMPERATURE (ºF)
*** (BTU/HR/FT)
EVAPORATOR
RATING CONDITION
TOP/FRONT
NSF 7
AHRI
NSF 7
AHRI 1200
230/530
230/530 26/26
26/26
90
90
26
26
DEFROST
DEFROST
TIME
FREQUENCY
TYPE
(MIN)
(#/DAY)
OFF TIME
30
4
CANOPY LIGHTS
LED TOP AND
FRONT
BLADE PITCH
AMPS WATTS AMPS WATTS AMPS WATTS
FRONT (°)
15
0.2
16
0.2
15
0.5
32
0.4
15
0.5
32
0.5
15
0.5
32
0.5
15
0.7
48
0.7
MAX. H.O. LED
OPTIONAL SHELF
LOAD
AMPS
WATTS AMPS WATTS
0.2
26
0.6
69
0.4
41
0.8
96
0.4
51
1.2
138
N/A
N/A
N/A
N/A
0.7
77
1.8
207
VELOCITY
TOP/FRONT
DISCHARGE
(FT/MIN)
AIR TOP/FRONT
**
NSF 7
NSF 7
33~36/32~36 50~100/150~200
32~34
600~725
TERM. TEMP
DEFROST
DRIP
(°F) COIL
WATER
TIME
ONLY
(LBS/DAY/FT)
45
N/A
0.6
45
N/A
48
N/A
2.8
45
0.2
N/A
OPTIONAL LED
MAX. LED LOAD
SHELF LIGHTS
(W/ ALL
TOP AND FRONT
OPTIONS)
AMPS WATTS AMPS WATTS
28
0.1
10
0.3
39
44
0.1
15
0.5
59
57
0.2
21
0.7
77
62
0.2
26
0.8
88
85
0.3
31
1.0
116
REFRIGERATED REAR STORAGE
(OPTIONAL) EVAP. FANS
# OF
BLADE
BLADE
EVAP
PITCH
DIA. (IN.)
(°)
FANS
1
6.70
30
1
6.70
30
6.70
30
1
6.70
30
1
1
6.70
30
22
REVISION DATE
EST.
20°F GLYCOL
REFG.
CASE
CHRG.
LENGTH
FRONT
404A
(LBS)
GPM
PSI
GPM
4'
1.8
0.7
1.7
0.4
6'
2.6
1.0
3.9
0.5
8'
3.5
1.4
1.8
0.7
10'
4.1
1.7
3.1
1.0
12'
5.2
2.0
3.7
1.0
END PANEL WIDTH KEY
END PNL
# OF END
TOTAL ADDED
WIDTH
PNLS
LENGTH (IN.)
(IN.)
1
1.125
1.125
1.125
1
1.125
2
1.125
2.25
ANTI-SWEAT
CONVENIENCE
HEATERS (ON
OUTLETS (OPTIONAL)
FAN CIRCUIT)
#
VOLTS
AMPS
OUTLETS
0.9
100
1
115
1.3
150
1
115
1.7
200
115
1
2.2
250
115
1
2.6
300
2
115
AMPS WATTS
0.3
8.8
0.3
8.8
0.3
8.8
0.3
8.8
0.3
8.8
9/11/2020
6° RISE
REAR
TOP
STORAGE
PSI
GPM
PSI
0.3
0.2
0.0
1.4
0.2
0.2
0.4
0.3
0.5
1.5
0.4
0.7
1.4
0.4
0.9
15
15
15
15
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr3hv-mf-ep

Table of Contents