6.11 Intel® Vroc 7.5 (Vmd Nvme* Raid) Key Replacement; Figure 92. Intel® Vroc Key Removal; Figure 93. Intel® Vroc Key Installation - Intel M20NTP1UR System Integration And Serive Manual

Table of Contents

Advertisement

Intel® Server System M20NTP1UR - System Integration and Service Guide
6.11 Intel® VROC 7.5 (VMD NVMe* RAID) Key Replacement
This section provides instructions for the replacement of an Intel® VROC Key in the system.
Required Tools and Supplies
Intel® VROC 7.5 Key – iPCs: VROCSTANMOD or VROCPREMMOD or VROCISSDMOD
Anti-static wrist strap and conductive workbench pad (recommended)
1. Power off the system and disconnect all cable from the back of the system.
2. Remove the system top cover (see
3. Remove the system air duct (see
4. Remove the riser card assembly (see
5. Carefully remove the Intel® VROC Key from the server board (See
Using the key pull tab, pull the key up until it disengages from the connector.
6. Locate and unpack the new Intel® VROC Key
7. Install the Intel® VROC Key to the connector on the server board (see
Position the Intel® VROC Key over the connector and ensure the alignment features of the key and
connector match.
Place the Intel® VROC 7.5 Key onto the pins of the connector and press it down until it is securely
in place
74
Section
6.1.1).
Section
6.2.1)
Figure
76)
Figure 92. Intel® VROC Key Removal
Figure 93. Intel® VROC Key Installation
Figure
92)
Figure
93)