CLM920 TD3 LTE Module Hardware Usage Guide
temperatur
Working mode: normal work
e work
Test duration: 24h
High temperature: 85℃
Low temperature: –40℃
Temperatur
Working mode: normal work
e cycle
Test duration: 30
Cycles;1h+1h/cycle
High temperature: 55 ° C
Low temperature: 25 ° C
Alternating
Humidity: 95% ± 3%
hot and
Working mode: normal work
humid
Test duration: 6
Cycles;12h+12h/cycle
High temperature: 85 ° C
Low temperature: –40 ° C
Temperature change time: <30s
Temperatur
Working mode: no packaging, no
e shock
Power on, do not boot
Test duration: 100
Cycles;15min+15min/cycle
Height 0.8m, 6 sides each time,
dropped to the horizontal marble
Drop test
platform
Working mode: no packaging, no
Power on, do not boot
Temperature: –40 ° C
Low
Working mode: no packaging, no
temperatur
power, no boot
e storage
Test duration: 24 h
Temperature: 85 ° C
High
Working mode: no packaging, no
temperatur
power, no boot
e storage
Test duration: 24h
Shanghai Yuge Information Technology co., LTD
A108-C
Function check: normal
RF indicator check: normal
Visual inspection: normal
JESD22-
Function check: normal
A105-B
RF indicator check: normal
Visual inspection: normal
JESD22-
Function check: normal
A101-B
RF indicator check: normal
Visual inspection: normal
JESD22-
Function check: normal
A106-B
RF indicator check: normal
Visual inspection: normal
IEC6006
Function check: normal
8-2-32
RF indicator check: normal
Visual inspection: normal
JESD22-
Function check: normal
A119-C
RF indicator check: normal
Visual inspection: normal
JESD22-
Function check: normal
A103-C
RF indicator check: normal
- 74 -