Symbol
Description
Treset
Low pulse width
VIH
RESET input high level voltage
VIL
RESET input low level voltage
Reset RESET timing is as follows:
The CLM920 TD3 module supports AT command reset, and the AT command is
at+cfun=1,1 to restart the module. Detailed instructions for viewing the CLM920 TD3 AT
instruction set manual.

3.5 USB interface

The USB interface of the CLM920 TD3 module provides a USB2.0 High-Speed
interface. The interface supports slave mode and does not support USB charging mode. USB
interface pins are defined as follows:
Pin number
71
70
69
Shanghai Yuge Information Technology co., LTD
Table 3-8 RESET pin parameters
Figure 3-10 Reset timing diagram
Table 3-9 USB interface pin definition
Signal name
USB_VBUS
USB_DM
USB_DP
Min
Typical
150
200
1.17
1.8
-0.3
0
IO
Description
PI
USB detection
IO
USB differential signal -
IO
USB differential signal +
Max
unit
450
ms
2.1
V
0.8
V