When re-installing: In order to avoid possible water system faults (e.g.,
clogging or blocking of valves), grease, oil or other slip lubricants should
never be used when assembling and installing water system parts.
4.21

Removing the Brew Unit Drive (M26) and Brew Unit Switches

1. Remove the top cover; see Section 001-4.5.
2. Remove the side casing; see Section 001-4.6.
3. Take out the brew unit if it wasn't previously removed.
4. From the brew unit side, remove the five T10 screws securing the brew unit drive.
See Figure 001-46, Item 1.