Miele CM6 Technical Information page 40

Countertop coffee systems
Hide thumbs Also See for CM6:
Table of Contents

Advertisement

Technical Information
Function
Component (press
OK to start or stop
activation)
Sensor value
Switch status
Total operating
hours
Operation
Options
R39 (cup warmer)
(CM 63x0 only)
R30-14 (heater NTC)
B3-4 (flow meter)
S87-1 (drip tray present switch)
B3-18 (water tank sensor)
S60-1 / S60-2 (brew unit position switches)
S87-2 (brew unit present switch)
S51-4 (grind amount step contact switch)
S87-5 (chute present switch)
S51-1 (ceramic valve step contact switch)
S60-3 (ceramic valve position switch)
S87-6 (spout present switch)
Total operating hours are displayed.
Display
Display backlight
Buzzer
(Touch-) sensors
(press the
touchpad to be
tested; the
number of the
touchpad sensor
is displayed)
40
Description
Activate: Press OK.
Deactivate: Press OK again.
Heater temperature
is displayed
Flow meter pulses per second
is displayed.
0 = Drip tray not inserted
1 = Drip tray inserted
0 = Not inserted or inserted but
empty
1 = Inserted and full
Move the brew unit to the
corresponding position and
compare with Table 001-6.
0 = Brew unit inserted and
locked
1 = Brew unit not inserted or
brew unit inserted but not
locked
0 = Activated
1 = Not activated
0 = Chute closed
1 = Chute open
0 = Activated
1 = Not activated
0 = Activated
1 = Not activated
0 = Not inserted
1 = Inserted
The display and the drink
touchpads light up.
The display text lights up.
Buzzer sounds
continuously.
Sensor 102 pressed
Sensor 103 pressed
Sensor 107 pressed
Sensor 108 pressed
Sensor 65 pressed
Sensor 26 pressed
Sensor 66 pressed
Sensor 16 pressed (press
only briefly)
Sensor 82 pressed (CM
63x0 only)
Sensor 69 pressed
Sensor 68 pressed (CM
63x0 only)
CM6
Press OK to start/stop
test
Press OK to stop test