CM6

Figure 001-46: Brew Unit Drive Screws

5. From the water tank side, remove the two T10 screws securing the pump/flow
meter mounting bracket (Figure 001-47, Item 1). Slide the mounting bracket
forward to release it.

Figure 001-47: Pump/Flow Meter Mounting-Bracket Screw

6. Remove the T10 screw securing the water tank sensor/drip tray present switch
mounting bracket assembly (Figure 001-48, Item 1) and release this assembly.