2. Remove the side casing; see Section 001-4.6.
3. Release the microswitch (Figure 001-43, Item 1) from its mounting bracket.
4. Disconnect all electrical connections from the microswitch.

Figure 001-43: Water Tank Sensor and Drip Tray Present Switch

4.19

Ceramic Valve (M29) Removal

1. Remove the top cover; see Section 001-4.5.
2. Remove the side casing; see Section 001-4.6.
3. Disconnect the ceramic valve from the power electronic.
4. Release any wires from the clips at the base of the valve assembly.
5. Remove the T10 screw securing the base of the valve assembly (arrow, Figure
001-44); slide the valve assembly out.
6. Disconnect the five water lines from the valve assembly.
7. Release and remove the ceramic valve from its mounting bracket.
54